Failure Analysis
Reliateck provides Failure Analysis Services for its customers. Most problems that occur with microelectronic Devices can be detected with the Failure Analysis Techniques that we can provide: - I/V characterization (curve trace)
- Micro probing
- Pico probing up to 3 GHz
- Optical microscopic examination
- Chemical or mechanical decapsulation
- Real time X-ray
- Scanning Acoustic Microscopy (C-SAM)
- Scanning Electron Microscopy (SEM) systems
- Energy Dispersive X-ray analysis (EDX)
- Emission Microscopy
- Hot spot analysis
- Chemical deprocessing
- Plasma etching
- Parallel lapping
- Cross sectioning
- Failure analysis reports
Failure Analysis Process Level Level 1 - External Visual Inspection
- Curve Trace
- X-Ray
- C-SAM
- FA Report
Level 2 - Decapsulation
- Optical Microscopy
- Probing
- Liquid Crystal/EMMI
- FA Report
Level 3 - Chemical Deprocessing
- Cross Sectioning
- SEM
- EDX
- Parallel Lapping
- FA Report
|
|
|